Facility monitoring and single zone leak detection
The RLE F200 solution couples leak detection and facility monitoring in one plug-and-play package. Designed to be simple and efficient, the RLE F200 monitors environmental parameters and protects data centre facilities from disastrous consequences.
Under one umbrella: environmental monitoring, control of complex parameters and leak detection
The RLE F200 supports up to 4 sensor inputs to deploy temperature sensors, temperature/humidity sensors or a combination of both. Eight digital inputs offer to monitor, if a door is open or closed or more complex parameters such as motion, fire alarms, airflow sensors or summary alarms from mission critical equipment including UPSs and generators. One relay output makes it possible to control an external device in the event of an alarm condition. Further the RLE F200 can supervise an SD-Z1 spot detector or up to 200 feet of RLE Technologies‘ patented leak detection sensing cable and inline SD-Z spot detectors.
All data at a glance via Web-GUI, DCIM or BMS
Once the monitoring connections are snapped into place, all the infomation and measurement data is displayed via the integrated and intuitive web interface. The setup and configuration can be done quickly and easily, and the interface can be used from any computer or mobile device. In addition all the data is accessable by third party SNMP or Modbus TCP/IP based DCIM or BMS applications.
Multiple alarm configuration and reporting options
The F200 system offers to configure multiple alarm configurations, including audible and visible indicators, integrated web interface, email messaging and SNMP traps. The dashboard displays the 50 most recent alarms and return to normal events (with date and time stamps for each).
The highlights of RLE F200 monitoring solution:
- Reliable monitoring of temperature and humidity and detection of water leaks and other conductive liquids
- Monitors four 1-wire sensors, eight digital inputs and one zone of leak detection
- Supervises a SD-Z1 spot detector or up to 200 feet of sensing cable and inline SD-Z spot detectors
- A relay output can control an external device in the event of an alarm condition
- Multiple alarm notification configurations including audible and visible indicators, integrated web interface, email messaging, and SNMP traps
- Plug-and-Play installation and setup
- USB powered
- Web-accessible with a clean, easy to use and mobile-friendly web interface
- Multiple alarm notification configurations including audible and visible indicators, integrated web interface, email messaging, and SNMP traps
- Modbus TCP/IP enables simple integration into BMS or DCIM applications
The modules of the Falcon F200 facility monitoring solution:
- 1WIRE-TS wired sensor for accurate temperature readings
- 1WIRE-THS wired sensor for accurate temperature and humidity readings
- SD-Z1 spot detector for monitoring leaks in confined zones
- SD-Z spot detector can be connected to sensing or non-sensing cables
- SC sensing cables for the detection of conductive fluids